Home / GSP Dashboard / Annual Report Preview

GSP Annual Report

5-021.52 COLUSA
2024 (OCT. 2023 - SEP. 2024)
Single Annual Report

GSP Annual Report Information Correspondences
Comments

04/01/2025 3:15 PM

2024 (OCT. 2023 - SEP. 2024)

Single Annual Report
5-021.52_WY_2024.pdf (80.2MB)
5-021.52_WY_2024.xlsx (24.3kB)
GSP 2024
Lisa Hunter (County of Glenn)

A Groundwater Extraction

Total Groundwater Extractions (AF)

562,100

Water Use Sectors

11,000
0
535,000
16,100
0
0
0
      
        

B Groundwater Extraction Methods

Meters

8,180
Direct
5-10 %
Flowmeter records of groundwater extraction for urban use from cities and for agricultural use from the Colusa Well Monitoring Pilot Program.
Estimated based on the typical field accuracy of meters, and the typical combined accuracy of volumes in urban distribution systems (accounting for metered groundwater, metered deliveries, unmetered deliveries, and apparent losses)

Electrical Records

0

        

        

Land Use

547,200
Estimate
20-30 %
Estimated from a water use analysis based on land use, ET, available surface water supplies, and ponding water use requirements (where applicable).
Typical uncertainty of a water use analysis approach, considering the combined uncertainty of other flow paths following the procedure described by Clemmens and Burt (1997). The uncertainties of other flow paths are quantified based on measurement device accuracy, technical literature, or professional judgment.

Groundwater Model

0

        

        

Other

6,720
Estimate
20-30 %
Estimated in urban and rural areas where flowmeter records were unavailable based on annual population data, monthly per capita water use requirements, and outdoor use information. Total rounded to match rounded total groundwater extraction (Part A).
Typical uncertainty when calculated from population, per capita water use, and outdoor use assumptions, considering the combined uncertainty of those data sources.

C Surface Water Supply

Total Surface Water Supply (AF)

1,543,500

Methods Used to Determine

CVP supply and local supply (Orland Project) surface water deliveries were summarized from USBR CVO reports and Tehama Colusa Canal Authority delivery reports (where applicable). CVP supplies available to managed wetlands were summarized from CVPIA Refuge Water Supply Program contract quantities and reported annual allocations to National Wildlife Refuges in the Colusa Subbasin.

Water Source Types

1,502,100
0
0
41,400
0
0
0
0

        

D Total Water Use

Total Water Use (AF)

2,105,600

Methods Used to Determine

Groundwater is determined following the methods described in Part B. Surface water is determined following the methods described in Part C. Totals are rounded.

Water Source Types

562,100
1,543,500
0
0
0

        

Water Use Sectors

11,000
0
1,953,100
108,500
33,000
0
0

        

E Change in Storage


Method used to calculate change in storage

Annual change in groundwater storage was calculated based on change in measured spring-to-spring groundwater elevations multiplied by the area of the Thiessen polygon associated with each groundwater level RMS well and a refined storage coefficient of approximately 0.063 (revised in the WY 2023 Annual Report to align the average change in groundwater storage from the 1990-2015 period to the average results from the C2VSimFG-Colusa model used in the GSP; earlier values have changed following the inclusion of this updated storage coefficient). Change in groundwater storage in WY 2024 represents the Spring 2023-Spring 2024 annual change in groundwater storage.

F Monitoring Network Module

SGMA Wells Elevation Readings Export (CSV)


General Sites Elevation Readings Export (CSV)

G PMA Module

PMA Implementation Updates Implementation Update Export (CSV) PMA Export (CSV)